IOy Ethernet I/O
BL197 SNMP IOy Ethernet IO
Item No.: BL197
SNMP Ethernet IO Module
Introduction
Features
Specifications
Download
Applications
BL197 SNMP Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The SNMP Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI SNMP IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT SNMP IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
Optional Protocols
Optional I/O Boards
The SNMP Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI SNMP IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT SNMP IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
BL197-Y11 | SNMP Protocol 8DI I/O Module |
BL197-Y11-Y11 | SNMP Protocol 16DI I/O Module |
BL197-Y11-Y11-Y11 | SNMP Protocol 24DI I/O Module |
BL197-Y11-Y21-Y31 | SNMP Protocol 8DI+8DO+4AI I/O Module |
Optional Protocols
BL190 | Modbus TCP |
BL191 | PROFINET |
BL192 | EtherCAT |
BL193 | Ethernet/IP |
BL195 | OPC UA |
BL196 | MQTT |
BL197 | SNMP |
BA190 | BACnet/IP |
BE190 | IEC104 |
Optional I/O Boards
IO Item no. | Function | Description |
Y11 | 8DI NPN | Logic 1: -3 ⋯ +5VDC; Logic 0: +15 ⋯ +30VDC |
Y12 | 8DI PNP | Logic 1: +15 ⋯ +30VDC; Logic 0: -3 ⋯ +5VDC |
Y21 | 8DO PNP | Logic 1: 24 VDC; Logic 0: High impedance |
Y22 | 8DO NPN | Logic 1: 0 VDC; Logic 0: High impedance |
Y24 | 4DO Relay | Max voltage: 250VAC/30VDC; Max current: 2A |
Y01 | 4DI+4DO NPN | DI wet or dry contact, DO NPN |
Y02 | 4DI+4DO PNP | DI wet or dry contact, DO PNP |
Y03 | 4DI+4DO Relay | DI wet or dry contact, DO relay output |
Y31 | 4AI 0/4-20mA Single-Ended | 0~20mA, 4~20mA analog input, resolution: 16 Bit |
Y33 | 4AI 0-5/10V Single-Ended | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y34 | 4AI 0-5/10V Differential | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y36 | 4AI ±5V/±10V Differential | -5~5V, -10~10V analog input, resolution: 16 Bit |
Y41 | 4AO 0/4-20mA | 0~20mA, 4~20mA analog output, resolution: 16 Bit |
Y43 | 4AO 0-5/10V | 0~5V, 0~10V analog output, resolution: 16 Bit |
Y46 | 4AO ±5V/±10V | -5~5V, -10~10V analog output, resolution: 16 Bit |
Y51 | 2RTD 3-Wire PT100 | 3-wire PT100 |
Y52 | 2RTD 3-Wire PT1000 | 3-wire PT1000 |
Y53 | 2RTD 4-Wire PT100 | 4-wire PT100 |
Y54 | 2RTD 4-Wire PT1000 | 4-wire PT1000 |
Y56 | Resistance Measurement | - |
Y57 | Voltage Measurement | - |
Y58 | 4TC | B/E/J/K/N/R/S/T Thermocouple |
Y91 | 4High Speed Counter | - |
Y61 | 4RS485/RS232 | - |
Y62 | 1CAN+3RS485/RS232 | - |
Description
BL197 SNMP Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select the I/O modules by physical interfaces, protocols, and I/O functions.
The SNMP Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI SNMP IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT SNMP IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
Optional Protocols
Optional I/O Boards
The SNMP Ethernet IO Module passing 12 EMC/EMI tests ensures reliability under strong electromagnetic interference.
Ordering Guides
Users can select 1-3 Y series IO boards according to their needs, such as BL197 with 3 Y11 (8DI) can be composed of 24DI SNMP IO module, and also supports mix and match such as BL197 with Y11 (8DI), Y31 (4AI), Y52 (2PT) can be combined into 8DI + 4AI + 2PT SNMP IO Module.
Naming Rules
IOy-Y
IOy-Y-Y
IOy-Y-Y-Y
Example
BL197-Y11 | SNMP Protocol 8DI I/O Module |
BL197-Y11-Y11 | SNMP Protocol 16DI I/O Module |
BL197-Y11-Y11-Y11 | SNMP Protocol 24DI I/O Module |
BL197-Y11-Y21-Y31 | SNMP Protocol 8DI+8DO+4AI I/O Module |
Optional Protocols
BL190 | Modbus TCP |
BL191 | PROFINET |
BL192 | EtherCAT |
BL193 | Ethernet/IP |
BL195 | OPC UA |
BL196 | MQTT |
BL197 | SNMP |
BA190 | BACnet/IP |
BE190 | IEC104 |
Optional I/O Boards
IO Item no. | Function | Description |
Y11 | 8DI NPN | Logic 1: -3 ⋯ +5VDC; Logic 0: +15 ⋯ +30VDC |
Y12 | 8DI PNP | Logic 1: +15 ⋯ +30VDC; Logic 0: -3 ⋯ +5VDC |
Y21 | 8DO PNP | Logic 1: 24 VDC; Logic 0: High impedance |
Y22 | 8DO NPN | Logic 1: 0 VDC; Logic 0: High impedance |
Y24 | 4DO Relay | Max voltage: 250VAC/30VDC; Max current: 2A |
Y01 | 4DI+4DO NPN | DI wet or dry contact, DO NPN |
Y02 | 4DI+4DO PNP | DI wet or dry contact, DO PNP |
Y03 | 4DI+4DO Relay | DI wet or dry contact, DO relay output |
Y31 | 4AI 0/4-20mA Single-Ended | 0~20mA, 4~20mA analog input, resolution: 16 Bit |
Y33 | 4AI 0-5/10V Single-Ended | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y34 | 4AI 0-5/10V Differential | 0~5V, 0~10V analog input, resolution: 16 Bit |
Y36 | 4AI ±5V/±10V Differential | -5~5V, -10~10V analog input, resolution: 16 Bit |
Y41 | 4AO 0/4-20mA | 0~20mA, 4~20mA analog output, resolution: 16 Bit |
Y43 | 4AO 0-5/10V | 0~5V, 0~10V analog output, resolution: 16 Bit |
Y46 | 4AO ±5V/±10V | -5~5V, -10~10V analog output, resolution: 16 Bit |
Y51 | 2RTD 3-Wire PT100 | 3-wire PT100 |
Y52 | 2RTD 3-Wire PT1000 | 3-wire PT1000 |
Y53 | 2RTD 4-Wire PT100 | 4-wire PT100 |
Y54 | 2RTD 4-Wire PT1000 | 4-wire PT1000 |
Y56 | Resistance Measurement | - |
Y57 | Voltage Measurement | - |
Y58 | 4TC | B/E/J/K/N/R/S/T Thermocouple |
Y91 | 4High Speed Counter | - |
Y61 | 4RS485/RS232 | - |
Y62 | 1CAN+3RS485/RS232 | - |